Acoustic Absorber - Reflective Panel

It is used as acoustic reflective panel, acoustic absorber panel, acoustic scattering (reflective) panel and acoustic reflector – absorber panels.

Acoustic reflective panel: Reflective acoustic panels allow the sound to spread in a balanced way into the room and hall. It is in the foreground with the task of reflecting, not the task of swallowing. A number of calculations must be made before the assembly process. With an acoustic design, the layout area and the shape of the panels change. It is generally used in sound recording studios to get quality sound. .

Acoustic absorber panel: Absorbent acoustic panels are wood types that are generally used indoors to absorb and reflect sound and to help regulate acoustic sound. Acoustic absorber panels are perforated and jointed. Primarily used on walls and ceilings.

Acoustic Absorber Panel Application Areas: Conference hall absorber panel, theater hall absorber panel, wedding hall absorber panel, movie theaters absorber panel, shopping mall absorber panel, restaurants absorber panel, call centers absorber panel, shooting ranges absorber panel, sports halls absorber panel, meeting halls are absorber panels, wedding halls are absorber panels.

G1L1 Acoustic Absorber - Reflective Panel

Thickness: 12, 18 mm – MDF LAM
Front Surface: Striped, distance between lines 32 mm, line depth 6 mm, line width 4 mm, average line 32 mt / m²
Rear Surface: Perforated, spacing between holes 32×32 mm, average 1000 holes / m², hole diameter 8 mm, 2 mm Acoustic Fabric coated

G2L1 Acoustic Absorber Reflective Panel

Thickness: 12, 18 mm – MDF LAM
Front Surface: Striped, distance between lines 32 mm, line depth 6 mm, line width 4 mm, average line 32 mt / m²
Rear Surface: Perforated, spacing between holes 32×16 mm, average 2000 holes / m², hole diameter 8 mm, 2 mm Acoustic Fabric coated

G2L2 Acoustic Absorber Reflective Panel

Thickness: 12, 18 mm – MDF LAM
Front Surface: Striped, distance between lines 16 mm, line depth 6 mm, line width 4 mm, average line 62 mt / m²
Rear Surface: Perforated, distance between holes 32×16 mm, average 2000 holes / m², hole diameter 8 mm, 2 mm Acoustic fabric covered

G3L2 Acoustic Absorber Reflective Panel

Thickness: 12, 18 mm – MDF LAM
Front Surface: Striped, distance between lines 16 mm, line depth 6 mm, line width 4 mm, average line 62 mt / m²
Rear Surface: Perforated, distance between holes 16×16 mm, average 4000 holes / m², hole diameter 8 mm, 2 mm Acoustic Fabric coated

G4L3 Acoustic Absorber Reflective Panel

Thickness: 12, 18 mm – MDF LAM
Front Surface: Striped, distance between lines 16 mm, line depth 6 mm, line width 4 mm, average line 124 mt / m²
Rear: perforated, distance between holes 16×8 mm, average 8000 holes / m², hole diameter 8 mm, 2 mm Acoustic fabric covered

Get Offer

SEND